Klein-tools CL2500 User Manual

Browse online or download User Manual for Measuring instruments Klein-tools CL2500. Klein Tools CL2500 User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 2
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
CUSTOMER SERVICE
KLEIN TOOLS, INC.
450 Bond Street
Lincolnshire, IL 60069
www.kleintools.com
139677 Rev. 11/13 B
ENGLISH
• 1000A AC/DC
• TRUE RMS
AUTO / MANUAL
RANGE
• NON CONTACT
VOLTAGE TESTER
MAX / MIN / HOLD
• ANALOG BAR GRAPH
• 3-5/6 DIGIT
5999 COUNT LCD
• BACKLIGHT
• WORKLIGHT
ENGLISH
8. Non Contact Voltage (NCV):
>
25V AC
SYMBOLS USED ON LCD
~
AC Measurement DC Measurement
-
Negative DC Value
AT
Auto Range Active
O
.L.
Overload: Range Exceeded
Apo
Auto Power-Off Active
Low Battery
HOLD
Hold Active
MIN
Minimum Reading
M
AX
Maximum Reading
%
Duty Cycle Mode Frequency Mode
V
Voltage Measurement
A
Current in Amps
Ω
Resistance in Ohms Diode Test
F
Capacitance in Farads Continuity Test
Relative / Zero Mode
n
Nano 10
-9
µ
Micro 10
-6
m
Milli 10
-3
k
Kilo 10
3
M
Mega 10
6
ELECTRICAL SPECIFICATIONS
DC Voltage Measurement
Range Resolution Accuracy
600mV
˜
600V 0.1mV
˜
0.1V ± (0.5% + 4 digits)
1000V 1V ± (0.8% + 10 digits)
Overload Protection: 1000V
AC Voltage Measurement
Range Resolution Accuracy
600mV
˜
750V 0.1mV
˜
1V ± (2.0% + 5 digits)
Overload Protection: 750V RMS
Frequency Response: 45 to 400 Hz
Minimum Voltage for Frequency Measurement: 200mV
Response: True RMS
DC Current Measurement
Range Resolution Accuracy
600µA 0.1µA
± (1.2% + 3 digits)
2000µA 1µA
60A 0.01A ± (2.5% + 15 digits)
600A ~ 1000A 0.1A ~ 1A ± (1.5% + 8 digits)
Overload Protection:
Voltage: 600V RMS
Current: 2000µA (leads), 1000A (clamp)
AC Current Measurement
Range Resolution Accuracy
600µA 0.1µA ± (2.0% + 5 digits)
2000µA 1µA ± (1.5% + 5 digits)
60A 0.01A ± (2.9% + 15 digits)
600A ~ 1000A 0.1A ~ 1A ± (1.9% + 8 digits)
Overload Protection:
Voltage: 600V RMS
Current: 2000µA (leads), 1000A (clamp)
Frequency: 45 to 400Hz
Minimum Current for Frequency Measurement: 400µA (leads) or 20A (clamp)
Response: True RMS
Resistance Measurement
Range Resolution Accuracy
600Ω
˜
6MΩ 0.1Ω
˜
0.001MΩ
± (1.0% + 4 digits)
60MΩ 0.01MΩ
± (2.0% + 4 digits)
Overload Protection: 600V RMS
Capacitance Measurement
Range Resolution Accuracy
60nF
˜
6000µF 0.01nF
˜
1µF ± (3.5% + 6 digits)
Overload Protection: 600V RMS
Frequency Measurement
Range Resolution Accuracy
99.99Hz
˜
499.9kHz 0.01Hz
˜
100Hz ± (0.1% + 4 digits)
Overload Protection: 600V RMS
Duty Cycle Measurement
Range Resolution Accuracy
0.1
˜
99.9% 0.1% ± (0.2% per kHz + 0.1% + 5 digits)
Overload Protection: 600V RMS
Diode Test
Overload Protection Range Test Current Open Circuit Voltage
600V RMS 6.0V Appx. 0.25mA
<
1.8V DC
Continuity Test
Overload Protection Open Circuit Voltage Threshold (Appx.)
600V RMS
<
0.44V
~40Ω
Non Contact Voltage Detector
On Voltage
Appx. 25V AC and above
WARRANTY
www.kleintools.com/warranty
CLEANING
Turn instrument off and disconnect test leads. Clean the instrument by using
a damp cloth. Do not use abrasive cleaners or solvents.
STORAGE
Remove the batteries when instrument is not in use for a prolonged period of
time. Do not expose to high temperatures or humidity. After a period of storage
in extreme conditions exceeding the limits mentioned in the Specifications
section, allow the instrument to return to normal operating conditions before
using it.
DISPOSAL / RECYCLE
Caution: This symbol indicates that equipment and its accessories
shall be subject to a separate collection and correct disposal.
750V
1000V
1000A
Dwg Name: CL2500-139677ART Dwg No: 139677
ECO No: 14678 Pkg Dwg Ref: 1650 Rev: B
Color Reference: CEN-PACK-003-A
Instruction Manual
CL2500
CL2500 Instruction Manuals - MASTER.indd 1-4 11/20/2013 2:57:08 PM
Page view 0
1 2

Summary of Contents

Page 1 - Instruction Manual

CUSTOMER SERVICEKLEIN TOOLS, INC.450 Bond StreetLincolnshire, IL 60069www.kleintools.com139677 Rev. 11/13 BENGLISH• 1000A AC/DC• TRUE RMS• AUTO / M

Page 2

ENGLISH5. Resistance: < 60MΩFeatures: MAX/MINRANGEHOLDIJFEATURE DETAILSCL2500 Instruction ManualGENERAL SPECIFICATIONSThe Klein Tools CL2500 is a

Comments to this Manuals

No comments